Test and Measurement Products (HDS2062M Handheld DSO 250MSPS)


Description


The HDS2062M handheld DSO has been specifically designed for the engineer or technician that requires an oscilloscope to be used on the bench or out in the field. Not only a fast, accurate Digital Storage Oscilloscope but the HDS2062M also incorporates a multi-function Digital Multimeter. The HDS2062M features a ruggered impact resistant casing, easy-to-use controls and high-brightness quality Sony LCD display. Battery life in an exceptional 6 hours. The HDS2062M with a generous array of standard accessories.


Product


Handheld 2-Channel Digital Storage Oscillscope
Sample rate up to 250MSPS, 60MHz bandwidth
12k/channel memory depth
3-3/4 digit DMM with datalogger
Manual cursor measurement
Li-ion battery and AC adapter
6 hour battery life
9.7 cm 320x240 Sony Colour LCD Display
RS-232, USB port for programming & data transferring
Edge triggering, video triggering, 5 automatic measurement
Independently floating isolated scope and DMM channels for safety
A profession ideal tool for design, maintenance and examination
Supplied complete with carry case, scope and DMM leads, CD and manual


Technical DetailsSolid brightness with 1600 lumens and a 4000:1 contrast ratio (with ImageAI ) Native 720p high-definition resolution with 16:9 aspect ratio Light and color processing technologies for remarkable picture quality and contrast levels Sleek and diminutive form factor at 4 pounds with extensive connectivity options Display Technology: 0.62” DarkChip2 DLP Technology by Texas Instruments Resolution: Native 720p (1280 x 720) Maximum Resolution: 1080p (1920 x 1080) Brightness: 1600 Lumens › See more technical details

Description

The HDS2062M is a handheld battery powered dual channel Digital Sampling Oscilloscope and Multimeter in one. It features a quality colour LCD display, easy-to-use controls and long battery life.
The HDS2062M comes complete with a wide range of useful functions, usualy only available in higher priced alternatives.
Display Modes
Normal - operates like a normal DSO with simple manual control of timebase, triggering etc
XY Mode - With the XY mode selected, CH1 is displayed on the horizontal axis and CH2 is on the vertical axis; when the oscilloscope is under the sampling mode in which no trigger is found, the data appears as light spots.
Auto-set - The Auto-Set feature lets the Oscilloscope display and measure unknown signals automatically. This function optimizes the position, range, timebase and triggering and assures a stable display of virtually any waveform.
Average Display - the displayed waveform is an average of a preset number of waveform samples. This can eleiminate noise which can otherwise obscure readings
Persistence mode - in this mode, the screen is not cleared in-between displaying a new waveform sample. Useful for detecting spurious waveform events which would otherwise be missed.
Peak Detection - The oscilloscope takes samples from the maximum and minimum of signals in each sampling interval - used to detect a jamming glitch and reduce the possibity of blurring
Automatic Measurements - The oscilloscope can perform 5 types automatic measurements such as frequency, cycle, average value, peak-to-peak value and root mean square value. And gives two kinds of measurement results simultaneously on the screen.
MATHS functions - shows the result of adding, subtracting, multiplying or dividing calculation on CH1 and CH2 channel waveforms

Waveform Display
Persistence mode
Video Signal Capture
Triggering
There are two triggering modes including Edge triggering and Video triggering.
Edge triggering: The Edge triggering is a mode by which trigger occurs at the triggering threshold value of the input signal edge. With the Edge triggering selected, the trigger happens on the rise or fall edge of the input signal
Video triggering: With Video triggering selected, the oscilloscope performs the NTSC, PAL or SECAM standard video signals field or line trigger
Multimeter
The HDS2062M can also be used in Multimeter mode, and used to make the following measurement;
Direct voltage measurement
Alternating voltage measurement
Direct current measurement
Alternating current measurement Resistance measurement
Diode measurement
Continuity buzzer measurement
Capacitance measurement Other Features
Waveform Storage - up to 4 waveforms can be saved in the HDS2062M's internal memory for comparison display or upload to a PC
Data Upload to a PC - Stored Data can be uploaded to a PC via RS232 or USB in bitmap or ASCII format.

Specifications DSO

Sampling Sampling modes Normal samplingPeak detectionAverage value Sampling rate 250 MS/s Input Input coupling DC, AC Input impedance 1MOhm;±2% connected in parallel with 20pF±3pF Probe attenuation coefficient 1X, 10X, 100X, 1000X Max. Input voltage 400V (peak) Channel delay time (typical) 150ps Horizontal Sampling rate range 10S/s 250MS/s Waveform interpolation sin x / x Record length 6K points on each channel Scanning speed range S/div 5ns/div 5s/div, stepping in the “1-2.5-5” mode. Sampling rate and relay time accuracy ±100ppm(any time interval which is equal to or larger than 1ms) Time interval(T)measurement accuracy full bandwidth Single: ±(1 sampling interval time+100ppm×reading+0.6ns)>average 16 : ±(1 sampling interval time +100ppm×reading+0.4ns) Vertical Analog digital converter A/D With the resolution of 8 bits, make sampling on both channels synchronously. Sensitivity range V/div 5mV/div 5V/div at the input BNC Displacement range ±50V(500mV 5V), ±1V(5mV 200mV) Analog bandwidth 60MHz Low frequency response AD coupling, -3dB 5Hz at the BNC Rise time typical one at the BNC 17.5ns DC gain accuracy 5% DC measurement accuracy average value sampling mode The voltage difference (V) between any two points on the waveform after averaging the captured waveforms more than16: ±(5% reading + 0.05 divisions). Trigger Trigger sensitivity Edge triggering DC coupling : CH1 and CH2: 1div(DC full bandwidth)AC coupling : Same as the DC coupling when it is equal to or larger than 50Hz. Triggering lever range ±6 divisions from the screen center Triggering level accuracy (typical) which is applicable to the signal with rise and fall time equal to or longer than 20ns ±0.3 divisions Trigger displacement 655 divisions for pre-triggering and 4 divisions for post- triggering Make a 50% level setting (Typical) Operation with the input signal frequency equal to or larger than 50Hz. Trigger sensitivity (Video triggering and typical mode) 2 divisions of peak-to-peak value Signal system and line/field frequency (Video triggering mode) Support the NTSC, PAL and SECAM broadcasting systems of any field or line frequency. Measurement Cursor measurement Voltage difference (V) and time difference (T) between cursors Auto measurement Peak-to-peak value, average value, root mean square value, frequency and cycle.
Multimeter
Voltage (VAC) TRMS Input Impedance 10MΩ Max. Input Voltage 1000V (DC or AC peak-to-peak value) Range Accuracy Resolution 400.0mv ±1%±1 digit 100uV 4.000V 1mV 4.000V 10mV 4.000V 100mV Voltage (VAC) Input Impedance 10MΩ Max. Input Voltage 750V (AC, virtual value) Frequency range from 40Hz to 400Hz. Display Virtual value of the sine wave Range Accuracy Resolution 4.000V ±1%±3 digit 1mV 4.000V 10mV 4.000V 100mV Voltage (VAC) Range Accuracy Resolution 40.00mA ±1%±1 digit 10uA 400.0mA ±1.5%±1 digit 100uA 20A ±3%±3 digit 10mA Resistance Range Accuracy Resolution 400.0Ω ±1%±3 digit 0.1Ω 4.000KΩ ±1%±1 digit 1Ω 40.00KΩ 10Ω 400.0KΩ 100Ω 4.000MΩ 1KΩ 40.00MΩ ±1.5%±1 digit 10KΩ Capacitance Range Accuracy Resolution 51.20nF ±3%±3 digit 10pF 512.0nF 100pF 5.120uF 1nF 51.20uF 10nF 100uF 100nF Diode Voltage reading 0V - 1.5V On-off Test 0V - 1.5V
General
Display Display type 3.8’’ color liquid crystal display Display resolution 320 (horizontal) × 240 (vertical) pixels Display color 4096 colors Operating Temperature Used battery 0 to 50 °C (32 to 122 °F) Power adapter 0 to 40 °C (32 to 104 °F) Storage Temperature Storage -20 to +60 °C(-4 to +140 °F) Operating Humidity 0 to 10 °C(32 to 50 °F) no condensation 10 to 30 °C(50 to 86 °F) 95 % 30 to 40 °C(86 to 104 °F) 75 % 40 to 50 °C(104 to 122 °F) 45 % Storage Humidity -20 to +60 °C(-4 to +140 °F) no condensation Accessories Two 1:1 (10:1) passive oscilloscope probes of 1.2 meters longA pair of test leads of multimeterA piece of serial-port data transmission lineA measuring extension module for small currentA measuring extension module for small capacitanceA power adapter in conformity with the standards of the host countryA User ManualAn operational optical disk

WebServer WS10 Web Datalogger


Description


The WebServer WS10 is a device for analogue and digital data acquisition, logging and transmission. It is capable of integrating instruments and sensors to the Internet, Ethernet and Wireless networks. The WS10 has built-in analogue and digital inputs or the I/O count can be increased using external Modbus based acquisition units. Data is logged to internal memory and can then be uploaded later through the Web, Ethernet or GSM or dial-up Modem. The WS10 also has built-in alarming.


Product


Internal memory for off-line data logging (16 bit CPU, with 512KB RAM)
2 Serial Interfaces (RS232, RS485 or Modem)
Ethernet 10BaseT Interface
It suports TCP/IP, PPP (client and server), HTTP, FTP, SMTP, DHCP, Modbus TCP, Modbus RTU protocols
Mobile wireless networks (GSM GPRS or CDMA 1XRTT)
email in case of alarm
Four inputs, configurable as: Digital inputs for counting voltage pulses or dry contacts, with totalizer for flow measurements.
0- 5V , 0-20mA or 4-20mA analogue inputsResolution: 1024 levels(10 bits) for 0-5V and 0-20mA
Analogue/Digital Expansion via External Units >>
800 levels for 4-20mA.
Accuracy: better than 0,3% of input full scale range.
Input impedance: >1M Ohms for 0-5V, 230 Ohms for current.
Pull-up resistor for digital inputs: 10KOhms / +5V.
Possible input types combination: 4 digital inputs
1 analogue and 3 digital inputs
2 analogue and 2 digital inputs
4 analogue inputs2 Relays Output
Ambient conditions: 0 a 55°C, 35% to 85% Relative Humidity, non condensing
ABS Housing for DIN Rail 35mm.
Dimension: 105x90x60mm
SMPS 85 to 264Vca / 50-60Hz / 4VA max.


Data Acquisition
The WS10 gets data from the system or process through:
4 built-in signal inputs
RS232 or RS485 serial communication interface
Data acquisition over the RS485 communication interface uses the Modbus RTU protocol. The WS10 acts as a master, polling the Modbus network nodes to get the specified data to its memory. All the data acquired from its local inputs and from external Modbus devices are stored on the WS10 memory. The user can assign identifiers for each memory position. On the configurations of the data access functions, all registers are referenced by their names.
The WS10 can be configured to periodically log data to its Flash memory. This historical logging can then be sent out by e-mail or directly to a computer. With a remote supervision system, this function enables the WS10 to monitor the process and send the acquired data periodically or when the communication link is established.
The instantaneous and historical values acquired from the system or process can be accessed via:
Ethernet interface
RS232, RS485 serial interface or Modem (conventional or mobile).
The WS10 offers five basic applications for remote data access of its data.
Web Browser Access
Modbus TCP or Modbus RTU
Alarm conditions supervision
E-mail transmission
Periodical data transmission
The WS10´s multi-task operating system allows for the simultaneous utilization of all these applications

Web Browser Access
The WS10 can present the acquired data of the process in dynamic user-created HTML pages, that can be visualized by any computer using a Internet browser (Netscape, Internet Explorer, etc). The WS10, connected to the company’s intranet by its Ethernet interface, shares the information (application data) to any computer connected to the intranet, allowing both reading and writing of data, with or without password authorization.
In a remote application, a WS10 connected to a conventional or mobile modem can answer a "dial-up" call connection and present a supervision page to the internet browser of the computer that originated the call, allowing the supervision of remote units.
MODBUS TCP
The WS10 can be configured as a ModbusTCP server and gateway, enabling integration to SCADA supervisory systems. As a server, WS10 accepts connections from multiple SCADA clients, allowing read and write access to its internal registers. This registers are associated to WS10’s local I/O, memory positions or external ModbusRTU devices. As a gateway, WS10 forwards messages between ModbusTCP and ModbusRTU networks, acting as a protocol converter. Both modes may be used simultaneously, while all other WS10 functions remain fully functional. ModbusTCP communication can be used over Ethernet or phone line (fixed or mobile).
Alarm Notification
Tthe WS10 can continuously compare the content of its registers against user programmed limits. The result of this comparison is assigned to a new register that can be used to trigger a local output, write in a remote equipment through the Modbus RTU, send an e-mail or send information to a remote server. The WS10 2 Relays can be activated in response to various alarms
email or Mobile Phone Messages
The WS10 can be configured to send e-mails automatically to an address list. The transmission can be periodical or by exception, based on register values. The e-mails are sent through the Ethernet or Modem and have a dynamic content, sending process data to the recipient. The message sending to cell phones can be done by email (depending on the routing service offered by the mobile phone operator) or directly to a GSM modem connected to the WS10. The e-mail may include, as an attached file, the historical data stored in its memory.
Periodic Data Transmission
The data acquired by the WS10 can be sent periodically to any accessible computer in the Ethernet or Internet (using a conventional or mobile Modem), being received by a TCP server application and stored in a place and format defined by the user. Both instantaneous and historical register values can be sent to the remote server.
Application Topology
Local Operation
Connected to a local network, WS10 can bridge a ModbusRTU network to existing SCADA using Ethernet, expanding data accessibility to virtually all networked computers using internet browser. WS10 can also log historical data, monitor alarm conditions and send e-mail messages in periodical or exception basis. WS10 is an alternative to SCADA in small applications. When the network connection to the internet is properly configured, WS10 data can be accessed from external locations, both by SCADA systems and browsers. The following figure shows WS10 in local application.

Remote Operation
Installed on a remote site, WS10 can connect through a modem to a fixed (optional internal modem) or cellular phone line. Using this connection, WS10 can access internet and send e-mail messages on abnormal conditions or periodically. WS10 can also transfer historical data to a networked computer. Its ability to answer data calls allows dial-up access using SCADA or browser. Remotely installed, WS10 allows additions functionalities when compared to conventional remote units that can only transfer data periodically. The following figure shows WS10 in a remote application.

Specifications
General
Switching power supply, 85 to 250Vac / 4VA.
Operating environment: 0 to 55°C, 35% to 85%RH, no condensation.
ABS housing for DIN rail mount. Dimensions: 105x90x60mm
Communication interfaces
Two serial interfaces with 6 pin RJ12 connection. Options:
RS232 (Com 1 Standard).
RS485 with optical isolation. Modbus RTU master or slave protocol (Com 2 stanard).
Internal V34+ Modem (Optional)Ethernet 10baseT. RJ45 connection.
Protocols: TCP/IP, PPP (client and server), HTTP, FTP, SMTP, DHCP, DNS, ModbusRTU (master and slave), ModbusTCP (server and gateway).
Inputs
Four configurable inputs:
Digital inputs for voltage pulse or dry contact. Flow measurement and totalizer function.
Analogue inputs for 0 to 5V, 0 to 20mA or 4 to 20mA.Resolution: 10 bits (1024 levels) for 0 to 5V and 0 to 20mA. 800 levels for 4 to 20mA
Analogue input accuracy: Better than 15mV or 0.06mA.
Pulse flow measurement time base accuracy: Better than 1s.
Pulse input maximum frequency: 200Hz with debounce disabled.
Input impedance: >1M 230ohm for current
Configurable input bias resistor: 10K
Allowable input configurations: 4 digital inputs
1 analogue and 3 digital inputs
2 analogue and 2 digital inputs
4 analogue inputs
Outputs
Two 250V/3A SPST relays.
Real Time Clock
Accuracy: ±3 minutes / month @ 25°C
Battery: CR2032 lithium cell.
Battery life: 10 years

AD-CM-DC Isolated Signal Converter


Description


A low-cost isolated signal conditioner module with DIP selectable input and output ranges. Accepts voltage and current inputs and can generate voltage or current outputs. DIN Rail mount.

Common Features



Industrial Signal Converter
2000V Opto-Isolation
Inputs : 0-5V, 1-5V, 0-10V, 0-60mV,4-20mA, 0-20mA
Outputs : 0-5V, 1-5V, 0-10V,4-20mA, 0-20mA
Selectable Dip Switch Ranges
Low Cost
DIN RAIL Mountable
Size (WDH) : 95 x 50 x 41 mm
Power : DC 24V ±10% (Internal SMPS included)
User Manual




Ranges

The signal converter AD-CM-DC will convert DC voltage or a direct current inputs to DC voltage or direct current output.
Inputs can be set using the SW1 DIP switch.
Outputs can be set using the SW2 DIP switch.
You may use Y terminal and B terminals for the inputs or the outputs.
Input Specifications
Input Signal
Input Impedence
Operating Temp. & Humid.
DC 0 to 5V
1M
-10 to 50 degrees Celcius, 10 to 95% RH
DC 1 to 5V
DC 0 to 10V
DC 0 to 60mA
DC 4 to 20mA
250
DC 0 to 20mA
Output Specifications
Output Signal
Allowable Impedence
DC 0 to 5V
Minimum of 2K
DC 1 to 5V
Minimum of 2K
DC 0 to 10V
Minimum of 4K
DC 4 to 20mA
Maximum of 500
DC 0 to 20mA
Maximum of 500
Input/Output Specifications
Factory Default Settings:
Input: 1 to 5V
Output: 0 to 20mA
Tolerance: +/- 0.25%
Maximum Input Setting Error: less than +/- 1%
Maximum Output Setting Error: less than +/- 1%
Maximum Temperature Variance: +/- 3% (Celcius)
Response Time: less than 50ms
Insulation Resistance: Minimum of 100 MΩ (Input/Output)
Withstanding-Voltage: AC 2000V for 1 min
Maximum Input Current: 90mA
Operating Temperature: -10°C to 50°C